UniFi Access Door Hub | UA-Hub-Door
UniFi Access Door Hub | UA-Hub-Door
一種單門機制,透過連接的進出控制讀卡器提供完整的進出控制。
(2) 鎖定終端(12V 和乾式)
(2) 用於外部警報器和自動門開啟器的 AUX 終端
(4) 額外輸入(感應器和按鈕)
使用 PoE++ 連接和供電
連接到兩個 UniFi Access 讀卡器和兩個 UniFi Protect 攝像頭或 UniFi Protect 門鈴
(有差異)
Mechanical Dimensions 174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3") Weight 363 g (12.8 oz) Enclosure material Polycarbonate Mounting material Polycarbonate Hardware Networking interface (5) 10/100/1000 Base-T Power method PoE++
UL 294 Power-limited Class 2 PSU
UL 60950-1/62368-1 LPS/PS2 PSUMax. power consumption Without PoE output: 30W
With PoE output: 50WPoE input 50V DC, 1A PoE output PoE passthrough, (4) PoE, 50V DC, total 20W LEDs White/blue (Learn more) Button (1) Factory-reset Digital input Request to exit/request to enter/remote release/door position sensor Dry output relay Lock: 30V DC, 1A
Aux: 30V DC, 1APowered output relay Lock: 12V DC, 1A
Aux: 12V DC, 0.33A
12V DC, 0.33ARecommend max. cable length 18 AWG
UACC-Cable-DoorLockRelay length20
AWG length22
AWG length24
AWG lengthUA-Lock-Electric
(400mA)100 m
(328 ft)66 m
(217 ft)42 m
(138 ft)25 m
(82 ft)UA-Lock-Magnetic-270kg
(800mA)46 m
(151 ft)30 m
(98 ft)20 m
(66 ft)12 m
(29 ft)UA-Lock-Magnetic-540kg
(500mA)80 m
(262 ft)51 m
(167 ft)32 m
(105 ft)20 m
(66 ft)Other locks
(1A)36 m
(118 ft)24 m
(79 ft)15 m
(49 ft)9 m
(30 ft)PoE cabling requirements Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords; 24 AWG (0.21 mm 2 ) for horizontal or riser cable.Operating environment Indoor use only Ambient operating temperature 0 to 40° C (32 to 104° F) Ambient operating humidity 5 to 95% noncondensing UL 294 level Destructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level IUL 294 statement Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.CAN/ULC-60839-11-1 Grade Grade assignment: 1 Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1 Document number, and issue date and/or revision level UA-Hub-Door002, V01